Error Code Lookup
Find the meaning and solution for error codes displayed on your Mitsubishi Electric products.
Select Product Category
Select Jet Towel Model
Error Pattern Results (9 results)
| Air volume lamp | Heater lamp | Operation OFF lamp | Operation ON lamp | Issue | Cause | Remedy | ||
|---|---|---|---|---|---|---|---|---|
| LED 5 | LED 4 | LED 3 | LED 6 | LED 2 | LED 1 | |||
| – | – | – | – | ○ | ☆ | Tamper prevention |
Foreign object was inserted, sensor window is dirty |
Automatic restart after removal of cause. View details |
| ☆ | ○ | ○ | ○ | ☆ | ☆ | Sensor abnormality |
Foreign object was inserted, sensor window is dirty |
Automatic restart after removal of cause. View details |
| ☆ | ☆ | ○ | ○ | ☆ | ☆ | Power-supply detection abnormality |
Electrical noise, or a faulty power circuit board |
Electrical noise: check the power. Faulty power circuit board: replace the power circuit board. View details |
| ☆ | ○ | ☆ | ○ | ☆ | ☆ | Motor abnormality |
Motor lock or connector disconnection |
Re-connect the connector or replace the blower assembly. View details |
| ☆ | ☆ | ☆ | ○ | ☆ | ☆ | Motor brush abnormality |
Motor brush abnormality, adhesion of foreign object |
Replace the blower assembly. View details |
| ○ | ○ | ☆ | ○ | ☆ | ☆ | Power circuit board temperature abnormality |
Overheated circuit |
Automatic restart after temperature is lowered. View details |
| ○ | ☆ | ☆ | ○ | ☆ | ☆ | Control circuit board temperature abnormality |
Overheated circuit |
Automatic restart after temperature is lowered. View details |
| ○ | ○ | ○ | ○ | ○ | ○ | Power-supply OFF |
Circuit breaker is off. |
Turn on the circuit breaker. View details |
| ○ | ○ | ○ | ○ | ○ | ○ | Abnormal voltage application/fuse melting |
Power fuse blowout |
Replace the power circuit board. View details |