Skip to main content

Error Code Lookup

Find the meaning and solution for error codes displayed on your Mitsubishi Electric products.

2

Select Jet Towel Model

3

Error Pattern Results (9 results)

○ Unlit ☆ Blinking (ON for 0.4 seconds / OFF for 0.4 seconds)
Air volume lamp Heater lamp Operation OFF lamp Operation ON lamp Issue Cause Remedy
LED 5 LED 4 LED 3 LED 6 LED 2 LED 1
– – – – ○ ☆

Tamper prevention

Foreign object was inserted, sensor window is dirty

Automatic restart after removal of cause. View details
☆ ○ ○ ○ ☆ ☆

Sensor abnormality

Foreign object was inserted, sensor window is dirty

Automatic restart after removal of cause. View details
☆ ☆ ○ ○ ☆ ☆

Power-supply detection abnormality

Electrical noise, or a faulty power circuit board

Electrical noise: check the power. Faulty power circuit board: replace the power circuit board. View details
☆ ○ ☆ ○ ☆ ☆

Motor abnormality

Motor lock or connector disconnection

Re-connect the connector or replace the blower assembly. View details
☆ ☆ ☆ ○ ☆ ☆

Motor brush abnormality

Motor brush abnormality, adhesion of foreign object

Replace the blower assembly. View details
○ ○ ☆ ○ ☆ ☆

Power circuit board temperature abnormality

Overheated circuit

Automatic restart after temperature is lowered. View details
○ ☆ ☆ ○ ☆ ☆

Control circuit board temperature abnormality

Overheated circuit

Automatic restart after temperature is lowered. View details
○ ○ ○ ○ ○ ○

Power-supply OFF

Circuit breaker is off.

Turn on the circuit breaker. View details
○ ○ ○ ○ ○ ○

Abnormal voltage application/fuse melting

Power fuse blowout

Replace the power circuit board. View details