Coolblade means not only comply with the severest environmental request but also the specific requirement. Its design satisfies the request for EFFICIENCY, FLEXIBILITY, OPERATING RELIABILITY and RESPECT FOR THE ENVIRONMENT. COOLBLADE has been created to show excellent performance which guarantees high air conditioning quality.
STANDARD CONFIGURATION
- Indoor unit and outdoor air-cooled condenser
- Outstanding rust protection thanks to galvanized steel sheet and powder-coated painting. The panels complete with internal soundproofing material
- Compressors and other key components from world leading brand such as COPELAND compressor
- Indoor fan adopts the high efficiency EC fan. The fans can fulfill maximum efficiency and low noise
- Electrical panel comply with IEC 204-1/EN60204-1
- Standard G4 filter, F5 is optional which is in accordance with CEN-EN 779, 90.1% filter efficiency, conforming to ASHRAE standard
- The microprocessor follows the FIFO to control the compressor’s start-up times. The unit can conveys the alarm and connect the customer’s receiving equipment automatically
- Other standard components: thermal expansion valve, high/low pressure safety switch, sight glass, dry filter, etc
Cooling Capacity
-
Cooling capacity: 25.1Kw-103Kw
Climaveneta modular air-cooled direct expansion CRAC indoor unit can be assembled on site. The indoor unit is divided into single system and double system, and the air supply mode is divided into lower air supply and upper air supply. The air-cooled direct-expansion machine room air conditioner adopts environmentally friendly refrigerant R410A.
Features and Benefits
- High-efficiency scroll compressor with high efficiency, low noise and low energy consumption
- The evaporator has a unique surface treatment (hydrophilic), and adopts special water treatment to solve the problem of condensed water droplets entering the air duct. The evaporator has a large area, and the fin material is specially treated, so it does not stick to water, the heat exchange effect is good, and the air pressure drop before and after the evaporator is small.
- Condenser end plate, side plate and hood of the outdoor unit coil are made of molded aluminum plate to protect the unit, the condenser is equipped with a large air volume and low noise fan, 46 degree condenser design, small size, light weight, easy to install, can be horizontal It can also be installed vertically on the wall, and can be installed in a variety of options. It can fully meet the requirements of various installation processes and has wide operating conditions.
- EC fan The impeller material is ultra-light polymer, which makes the operation noise of the computer room AC lower, and the energy saving rate is more than 10%. Inverter fans are not only better than AC fans in terms of energy saving and noise, but also better meet the requirements of today’s data centers in terms of control strategies. The computer room air conditioner allows users to remotely read the fan speed, and combined with the upper air pressure sensor, it can also realize advanced functions such as constant air pressure control.
The fan wall unit is one universal solution for the cooling system of data center which with low initial investment, faster installation and space optimization performance.
Data centers generate a significant amount of heat due to the operation of servers and other hardware. Efficient cooling is crucial to maintain optimal operating conditions and prevent equipment overheating. A fan wall unit may offer a cost-effective alternative with lower upfront expenses.
Features and Benefits
The rack cooler air conditioner is used to solve the cooling problem in the high heat density area of the computer room and as an auxiliary refrigeration device to solve the local hot spot problem in the computer room. Climaveneta air-cooled rack cooler air conditioners, all series of standard high-efficiency scroll or brushless DC inverter compressors, low-noise EC fans, CAREL’s new generation controller, and electronic expansion valves make the unit have the best cooling performance. The whole system also supports a variety of installation schemes for up and down pipes and up and down wiring. The frame of the unit is 300mm and 600mm, and the size of the unit can be customized according to the project requirements.
Advantage
- Flexibility and Modular Design
- Data Center extension
- Extreme flexibility (applicability to 42U &48U racks)
- Small floor standing area (0.3m”)
- Hot spot management
- Plug&Play connections for a quick and easy installtion
- Dual coil and redundant ATS is available
- EC fans keep running even during maintenance
- Rolling wheels under the frame for unit movement
- Humidifier (Optional)
Data Center Magnetic Levitation Oil Free Phase Change Cooling System : PCCS
- Air-cooled PUE ≤ 1.19 | Zero WUE
- Evaporative cooled PUE ≤ 1.15 | Low WUE
- Integrated VRF, Magnetic Levitation and Oil Free Technology.
Features and Benefits
-
Energy saving, high efficiency, simple operation and maintenance
-
Oil-free magnetic levitation technology: It can eliminate oil system maintenance, friction loss, bearing/resistance loss
-
Permanent magnet synchronous DC motor technology: It can eliminate the mechanical loss caused by the gearbox, and the motor efficiency is as high as 98%
-
Frequency conversion technology: stepless speed regulation, starting current as low as 2A, extremely high partial load Efficiency
-
Low pressure ratio technology: The compressor has a wide speed regulation range of 18500~52000RPM to meet the needs of different pressure ratios and cooling load
-
Free cooling technology does not need to run the compressor, which significantly improves the energy efficiency of the system.
-
The equipment is directly placed outdoors, without occupying the internal space of the equipment room and without setting up an equipment room.
-
Applicable to a wide range of areas, regardless of region, regardless of new or renovation projects, de-engineered design, modular construction.
-
Multi-connection modules, easy on-site installation, saving installation space, and de-engineering to the greatest extent
AIR COOLED OUTDOOR UNIT
- No water consumption, saving operating costs - Application of power heat pipe technology
Features and Benefits
-
The use of refrigerant to directly transport cold capacity is more than 8 times larger than the capacity of chilled water to transport cold capacity, which significantly reduces the flow of refrigerant transport and greatly reduces the transport power. Usually, the transport power of the refrigerant pump is less than one-fifth of the power of the water pump.
-
There is no water in the system, no antifreeze, no need to clean the heat exchanger regularly, the maintenance of system is simple, which can ensure the long-term stability of the system performance.
-
The system is filled with refrigerant, and the copper pipes are connected, so there is no danger of flooding in data center room.
-
It increases the system evaporating temperature, thus increases the cooling capacity and improves the efficiency the of the system significantly.
-
No water consumption, environmental friendly, more suitable for water-scarce or no-water areas.
WATER COOLED OUTDOOR UNIT
- Save space for outdoor units - Water cooling technology
Features and Benefits
-
Suitable for areas with plenty of water
-
One cooling tower can be connected to multiple pump cabinets, and the outdoor unit has a small footprint
-
The switching temperature point of free cooling can be increased by 5-7°C which means that the unit can have a longer free cooling operation time
Evaporative cooled
- Further improve energy efficiency - Evaporative cooling technology
Features and Benefits
-
The outdoor unit uses the latent heat of vaporization of water for heat exchange, and the condensation temperature is related to the wet bulb temperature. Comparing with the traditional condenser + cooling tower, the evaporative condenser can decrease the condensation temperature by about 6 degrees, and the energy efficiency can be increased by 20%.
-
The temperature point of free cooling can be increased by 5-7°C, which means the unit provides free cooling at higher temperature and a longer free cooling operation time.
-
The water pump equipped with the evaporative condenser only needs to carry out the internal water flow circulation, and the conveying distance is shorter; There is only the phase changing heat to be rejected, and the required circulating water volume is smaller, so the water pump can be significantly smaller than the cooling tower water pump, The power consumption is significantly reduced, which improves the system efficiency significantly.